Ethylene oxide sterilizer
[Air replacement] Automatic ventilation, the number and interval of ventilation can be set freely.
[Full-automatic control system] One-touch start to finish, the whole process is automatically completed with printing records.
[Display status] Display temperature, humidity, pressure, disinfection time, residual gas treatment time and frequency.
[Printer] Record and print the disinfection information for the whole process for verification.
[Humidity sensor] The built-in humidity sensor automatically detects the humidity in the cavity to ensure that the humidity in the cavity is not less than 45% RH.
[Pressure sensor] The built-in pressure sensor automatically detects the pressure in the cavity to ensure effective disinfection of the pressure in the cavity.
[Temperature sensor] The built-in temperature sensor automatically detects the temperature in the cavity to ensure that the temperature in the cavity is maintained within the disinfection range of 50 ° C ± 3 ° C.
[Humidification system] Pulsed humidification under vacuum conditions, to ensure that the humidity in the cavity is uniform and controllable; the humidity in the disinfection room should be controlled within the range of relative humidity 45% -80%.
[Residual gas treatment device] The removal rate of the filter with a particle diameter ≥ 0.3 μm is not less than 99.5%.
[Leak rate in sterilization room] The leakage rate is measured under the condition of no-load and sterilization room temperature, the test pressure is -50kPa, and the measurement time is 1h.
[Vacuum speed] Under no-load conditions, the time for the disinfection cabinet to reach -60kPa from normal pressure should be ≤30min.
[Vacuum system] The oil-free vacuum pump is used, which is simple and convenient, the vacuum rate is fast, and the service life is long.
[Heating system] It adopts explosion-proof electric heating device, which is more convenient and quick.
[Tray rack] Use 304 stainless steel tray rack.
[Various protection functions] With over-voltage and over-temperature protection function, it is more safe and reliable.
[Casters] Yes.
[Alarm system] There is a high temperature alarm system and an ultra-low pressure alarm system; when the disinfection temperature of the disinfection room exceeds 59 ° C, it should be able to sound an alarm.
[Category] Class II medical instruments.
HTY series ethylene oxide sterilizer is a kind of use of pure ethylene oxide and ethylene oxide mixed gas at a certain temperature, pressure, humidity and-a fixed period of time, for the items enclosed in the sterilization chamber special equipment for low temperature fumigation. Ethylene oxide gas is a very active chemical disinfectant, which can not only achieve broad-spectrum sterilization, but also achieve a reliable sterilization effect.
Advantages
Simple operation: one-button operation, microcomputer control, simple and convenient, digital display of sterilization process.
Print records: Record and print sterilization information for sterilization process, which is convenient for verification and archiving.
Filtration system: The air inlet is equipped with a filtration system, which can effectively filter out germs and microorganisms and avoid secondary pollution during exhaustion.
Application: Hysteroscopy, Laparoscopy, Laryngoscope, Probe, Rigid Endoscope, Hose Endoscope, Ophthalmic Lens, Fiber Optic Cable, Cranial Pressure Sensor, Cold Therapy Probe, Prostatectomy Device, Esophageal Dilator, Electrocautery Devices, defibrillation electrodes, laser head metal, glass, silicone, Chinese medicine and western medicine, human implants, masks, DNA, etc.
Contact Inofrmation :
Vivi Chen
Head Office Add:Xiangjiang Road,Industry Zone,Hua County,Henan Province,China
R&D Center Add:,26 building, No.1 Cuizhu Street,High-Tech Zone, Zhengzhou ,China
Mobile : 86-15737289626